Transfer Line (TK)
TK_1 (entrance) | Foilstripper | TK_9 (exit) | |
Bunch Frequency | 36.136 MHz | 36.136 MHz | 36.136 MHz |
W [MeV/u] | 11,4 | 11,4 | 11,4 |
β [%] | 15,591 | 15,591 | 15,591 |
100% Horizontal Rms-Emittance, norm. [mm·mrad]* | 0,349 | 0,351 | 0,345 |
100% Vertical Rms-Emittance, norm. [mm·mrad]* | 0,298 | 0,454 | 0,532 |
95% Longitudinal Rms-Emittance [mm·mrad]* | 0,465 | 0,518 | 0,831 |
Particle Transmission in Relation to RFQ-Input [%]* | 87,6 | 86,0 | 85,7 |
*(only for 238U28+ , resp. 238U73+)
The quoted beam intensties and beam power values refer to the theoretical current limit of the prestripper
Reference Ions | 130Xe2+ | 238U4+ | 20Ne1+ |
A/z (after stripping) | 2,8 | 3,3 | 2,0 |
Stripping Efficiency [%] | 20 | 15 | 90 |
Magnetic Rigidity [Tm] (before Stripping) | 3,0 | 4,1 | 1,4 |
Magnetic Rigidity [Tm] (after Stripping) | 1,3 | 1,6 | 1,0 |
Beam Intensity [emA] (at Foilstripper) | 57,0 | 32,9 | 20,0 |
Beam Intensity [emA] (at SIS Entrance) | 11,4 | 4,9 | 18,0 |
Beam Power (Pulse) [kW] (at Foilstripper) | 1798 | 1221 | 456 |
Beam Power (Pulse) [kW] (at SIS Entrance) | 360 | 183 | 410 |
Power (average) [kW] (Duty Factor 2 %) (at Foilstripper) | 36,0 | 24,4 | 9,1 |
Power (average) [kW] (Duty Factor 2 %) (at SIS Entrance) | 7,2 | 3,7 | 8,2 |