length” is from the Super-FRS target. 1st-order transfer matrix elements at the focal planes in the Pre-Separator Matrix element FPF1 FPF2 FPF3 FPF4 (x,x) -2.94 1.72 -2.75 2.00 (x,a) 0.03 (x,d) 4.39 -2 [...] the magnetic rigidity of 20Tm. In the figure 1, the beam plot with 3 rd -order ion-optics of the Pre-Separator is shown. The table below gives the calculated 1 st -order transfer matrix elements at the focal [...] -2.58 4.07 (a,a) -0.34 0.58 -0.37 0.50 (a,d) 0.52 0.53 (y,y) -5.65 -2.07 4.23 1.52 (y,b) 2.65 -0.05 -2.60 0.06 (b,b) 0.01 -0.46 0.03 0.57 Path length (m) 22.00 35.60 49.34 71.50 In the figure below in the
“path length” is from the Super-FRS target. FHF1 is 7.5 m from the end of the last quadrupole, FHF1QT32. Matrix element FMF1 FMF2 FMF3 FMF4 (x,x) -4.21 1.73 -4.21 2.5 (x,a) (x,d) 6.40 -5.25 6.40 (a,a) [...] a) -0.24 0.58 -0.24 0.40 (a,d) 0.12 -0.13 (y,y) -1.72 2.24 -1.52 3.78 (y,b) -0.05 -0.05 -0.05 (b,b) -0.52 0.45 -0.54 0.29 Path length (m) 98.08 123.86 149.64 180.72 [...] High-Energy Branch In the beam plot of the Main Separator shown, the end focus at FHF1 is chosen as 7.5 m beyond the end of the last quadrupole in the HEB. This large distance is needed to transport the
quadrupole, FLF2QT32. 1st-order transfer matrix elements at the focal planes in the LEB. Matrix element FLF1 FLF2 (x,x) 3.67 -2.00 (x,a) (x,d) -5.57 (a,a) 0.27 -0.50 (a,d) (y,y) 1.49 -2.01 (y,b) 0.14 -0 [...] isotopes. The ion-optics up to FMF3 are similar to the High-Energy Branch. The table below gives the 1 st -order transfer matrix elements at the focal planes in the Low-Energy Branch of the Main-Separator
of the last quadrupole, FRF3QT32. 1st-order transfer matrix elements at the focal planes in the Ring Branch. Matrix element FMF1 FMF2 FRF1 FRF2 FRF3 (x,x) -4.18 1.84 -1.82 4.18 -2.00 (x,a) (x,d) 6.35 -5 [...] -5.59 5.52 -6.35 (a,a) -0.24 0.54 -0.55 0.24 -0.50 (a,d) 0.09 0.03 (y,y) 0.25 0.11 1.34 1.37 (y,b) -0.61 0.63 -0.76 1.34 -0.10 (b,b) -0.19 0.03 -0.25 -0.36 0.71 Path length (m) 98.08 123.86 150.46 176.24 [...] that of the other branches, particularly in the vertical ( y ) dimension. The table below gives the 1 st -order transfer matrix elements at the focal planes in the Ring Branch of the Main-Separator. The
Eugenia Toimil-Molares GSI Helmholtzzentrum für Schwerionenforschung GmbH Materials Research Planckstraße 1 64291 Darmstadt Germany Working area : Nanostructures fabricated by ion-track technology Position :
and N. A. Tahir Entropy shaping by shock decay Physics of Plasmas 23 (2016) 112704 ; doi: 10.1063/1.4967463 M. Prall, M. Durante, T. Berger, B. Przybyla, C. Graeff, P. M. Lang, C. LaTessa, L. Shestov [...] electrons at fusion-relevant environmental conditions Journal of Physics: Conference Series. Vol. 688 . No. 1. IOP Publishing, 2016 M. Roth, D. Jung, K. Falk, N. Guler, O. Deppert, M. Devlin, A. Favalli, J. Fernandez
diagram of the plasma parameter for the present conditions. Dotted line: Doppler limit of Mg+ ions of 1 mK. Gray area: possible ion number densities in thermal equilibrium CCD image of an ion crystal Download
diagram of the plasma parameter for the present conditions. Dotted line: Doppler limit of Mg+ ions of 1 mK. Gray area: possible ion number densities in thermal equilibrium CCD image of an ion crystal Download
Wed, August 28, 2024 | 2 p.m. Kosmische Alchemie der Elemente – Die ersten 14 Milliarden Jahre des Universums Karlheinz Langanke, GSI/FAIR Registration and further information