Resonator

RFQ

Superlense

IH1

IH2

Frequency

36.136 MHz

36.136 MHz

36.136 MHz

36.136 MHz

Tank Length [m]

9,35

0,8

9,1

10,3

Inner Tank Diameter [m]

0,762

0,86

1,829

2,034

Energy Range [keV/u]

2.2 -120

120

120 - 743

743 -1395

β [%]

0.217-1.605

1,605

1.605-3.995

3.995-5.473

100% Horizontal Rms-Emittance, norm. [mm·mrad]

0,050

0,069

0,085

0,111

100% Vertical Rms-Emittance, norm. [mm·mrad]

0,050

0,069

0,085

0,111

100% Longitudinal Rms-Emittance [keV/u·ns]

0,139

0,250

0,390

0,446

Particle Transmission in Relation to RFQ-Input [%]

89

88

88

88

130Xe2+ (A/z = 65)

Max. Electrode Voltage [kV]

137

212

1150

1050

Effective Acceleration Voltage [MV]

7,7

-

40,5

42,7

RF-Powerloss, Pulse [kW]

290

75

1040

1050

RF-Powerloss (average), Duty Factor 2% [kW]

6

2

21

21

Beam Power [kW]

126

-

668

705

238U4+ (A/z = 59.5)

Max. Electrode Voltage [kV]

125

194

1053

961

Effective Acceleration Voltage [MV]

7

-

37

39

RF-Powerloss, Pulse [kW]

243

63

871

880

RF-Powerloss (average), Duty Factor 2% [kW]

5

1

17

18

Beam Power [kW]

106

-

560

591

20Ne1+ (A/z = 20)

Max. Electrode Voltage [kV]

42

65

354

323

Effective Acceleration Voltage [MV]

2,4

-

12,5

13,1

RF-Powerloss, Pulse [kW]

27

7

98

99

RF-Powerloss (average), Duty Factor 2% [kW]

0,5

0,1

2,0

2,0

Beam Power [kW]

12

-

63

67

238U10+ (A/z = 23.8)

Max. Electrode Voltage [kV]

50

78

421

384

Effective Acceleration Voltage [MV]

3

-

15

16

RF-Powerloss, Pulse [kW]

39

10

139

141

RF-Powerloss (average), Duty Factor 30% [kW]

11,7

3,0

41,8

42,2

Beam Power [kW]

-

-

-

-


Loading...